For the respiratory measurement (Resp), the monitor measures the thoracic impedance between two ECG electrodes on the patient’s chest. Changes in the impedance due to thoracic movement produce the Resp waveform on the monitor screen. The monitor counts the waveform cycles to.
This course provides an introduction to the Philips Intellivue MP monitor family, e.g. MP2,MP5,MP20/30, MP40/50, MP60/70, MP80/90. It focuses primarily on equipment operation, configuration, maintenance and minor repair. Monitor principles, board level theory and system diagnostics are learned.
And with Smart Pulse technology, you can differentiate between maternal pulse and fetal heart rate without the need of an additional sensor like SpO2 and ECG, even when monitoring multiples. View the brief video featuring Gloucestershire Royal Hospital in the UK and Heidelberg Women’s Hospital in Germany to learn more. Download 4549 Philips Monitor PDF manuals. User manuals, Philips Monitor Operating guides and Service manuals. If the transmitter is a standard ECG transmitter, replace with a 3- or 5-wire leadset. If the transmitter is an EASI ECG transmitter, a 5-wire must be used. If the transmitter is an EASI ECG transmitter, this INOP will appear if monitoring is attempted while a 3-wire leadset is attached to the transmitter. Attach a 5-wire leadset.
Refurbished
2.00 LBS
Ships in 24 hours
Philips Telemetry Monitor Manual Download
Calculated at checkout
Product Description
The Philips M2601A Telemetry system transmitter sends continuous ECG and SpO2 measurements to the IntelliVue Information Center, where the measurements are captured, analyzed, displayed, and stored. The basic setup comes with 3-lead or 5-lead capability. The ECG-only transmitter is particularly light and comfortable for patients. Upgraded transmitters combine standard and EASI derived 12-lead ECG monitoring on a single device, run on easily replaceable AA batteries, and provide audio feedback for many tasks, including “power on” and SpO2 spot check.
Features:
Frequency of 460-480 MHz or 608-614 MHz WMTS
Lightweight—less than ½ lb.
Standard ECG configuration with 3- or 5-lead capability
EASI ECG configuration used for transmitters that work with central stations that are capable of converting a 5-wire lead set signal to 12 lead analysis by having EASI version software installed at the central station.
SpO2 configuration used for transmitters that are used with SpO2 sensors.
Philips 5 Lead Dual ECG Leadwire - Snap ($55)
Philips 5 Lead Single Pin w/Tele Shield ECG Leadwires - Grabber ($95)
Add SpO2 Probe (Only Available with S02 Model):